Performance indicators for storage facilities marketed by RAG Energy Storage.
Status: 01.01.2026
| Sum of storage facilities marketed by RAG Energy Storage | |
|---|---|
| Working gas volume | 36,184 GWh |
| Max. withdrawal capacity | 15,605 MW |
| Max. injection capacity | 14,005 MW |
| UGS Puchkirchen/Haag | |
|---|---|
| Working gas volume | 13,400 GWh |
| Max. withdrawal capacity | 6,300 MW |
| Max. injection capacity | 6,300 MW |
| UGS Aigelsbrunn | |
|---|---|
| Working gas volume | 1,500 GWh |
| Max. withdrawal capacity | 575 MW |
| Max. injection capacity | 575 MW |
| UGS Haidach 5 | |
|---|---|
| Working gas volume | 184 GWh |
| Max. withdrawal capacity | 230 MW |
| Max. injection capacity | 230 MW |
| UGS Haidach (marketed by RAG Energy Storage) | |
|---|---|
| Working gas volume | 14,800 GWh |
| Max. withdrawal capacity | 5,900 MW |
| Max. injection capacity | 5,200 MW |
| UGS 7Fields (marketed by RAG Energy Storage) | |
|---|---|
| Working gas volume | 6,300 GWh |
| Max. withdrawal capacity | 2,600 MW |
| Max. injection capacity | 1,700 MW |
Reserved and free capacity at our storage facilities are as follows:
Withdrawal Capacity (WCI) | Working Gas Volume (WGV) | |||||
|---|---|---|---|---|---|---|
Year | WCI Reserved* | WCI | WCI Free* | WGV Reserved* | WGV | WGV Free* |
2026 | 15,505 MW | 100 MW | 0 MW | 35,609 GWh | 575 GWh | 0 GWh |
2027 | 13,157 MW | 100 MW | 2,348 MW | 35,461 GWh | 575 GWh | 148 GWh |
2028 | 11,488 MW | 100 MW | 4,017 MW | 32,641 GWh | 575 GWh | 2,968 GWh |
2029 | 6,493 MW | 100 MW | 9,012 MW | 14,118 GWh | 575 GWh | 21,481 GWh |
2030 | 4,883 MW | 100 MW | 10,622 MW | 10,613 GWh | 575 GWh | 24,996 GWh |
* exkl. Non-TPA
Basically, injection and withdrawal capacity are booked consistently, therefore only withdrawal capacity is illustrated in the table above.
GWh, MW ... thermal with a gross calorific value of 11.5 kWh/m³.
A description of the procedure for sending enquiries about capacities to RAG Energy Storage, and the related enquiry form as well as the documentation are available in the Download area.
Storage customers are entitled to offer their capacities on a secondary market (e.g. plattforms like PRISMA)
©